<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD with MathML3 v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3-mathml3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="research-article" dtd-version="1.3" xml:lang="en">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">JRNM</journal-id>
      <journal-title-group>
        <journal-title>Journal of Radiation and Nuclear Medicine</journal-title>
      </journal-title-group>
      <issn pub-type="epub">2766-8630</issn>
      <publisher>
        <publisher-name>Open Access Pub</publisher-name>
        <publisher-loc>United States</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.14302/issn.2766-8630.jrnm-20-3288</article-id>
      <article-id pub-id-type="publisher-id">JRNM-20-3288</article-id>
      <article-categories>
        <subj-group>
          <subject>research-article</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Entrance Surface Dose (ESD) Measurement During Pediatric Chest X-Rays</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Roya</surname>
            <given-names>Davoodi</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Mohammad</surname>
            <given-names>Reza Eydian</given-names>
          </name>
          <xref ref-type="aff" rid="idm1842429540">2</xref>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-5629-4130</contrib-id><name>
            <surname>Reza</surname>
            <given-names>Rezazadeh-Farokh</given-names>
          </name>
          <xref ref-type="aff" rid="idm1842426588">1</xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Asma</surname>
            <given-names>Maraei</given-names>
          </name>
          <xref ref-type="aff" rid="idm1842426588">1</xref>
          <xref ref-type="aff" rid="idm1842429108">*</xref>
        </contrib>
      </contrib-group>
      <aff id="idm1842426588">
        <label>1</label>
        <addr-line>Department of Medical Engineering, School of Technical and Engineering, Dezful Branch, Islamic Azad University, Dezful, Iran</addr-line>
      </aff>
      <aff id="idm1842429540">
        <label>2</label>
        <addr-line>Department of Radiology, Ganjavian Hospital, Dezful University of Medical Sciences, Dezful, Iran</addr-line>
      </aff>
      <aff id="idm1842429108">
        <label>*</label>
        <addr-line>Corresponding author</addr-line>
      </aff>
      <contrib-group>
        <contrib contrib-type="editor">
          <name>
            <surname>Qiuqin</surname>
            <given-names>Tang</given-names>
          </name>
          <xref ref-type="aff" rid="idm1842259148">1</xref>
        </contrib>
      </contrib-group>
      <aff id="idm1842259148">
        <label>1</label>
        <addr-line>Obstetrics and Gynecology Hospital Affiliated to Nanjing Medical University, China.</addr-line>
      </aff>
      <author-notes>
        <corresp>Corresponding author: Asma Maraei, Department of Medical Engineering, School of Technical and Engineering, Dezful Branch, Islamic Azad University, Dezful, Iran. Email: <email>asmamaraei@yahoo.com</email></corresp>
        <fn fn-type="conflict" id="idm1843200244">
          <p>The authors have declared that no competing interests exist.</p>
        </fn>
      </author-notes>
      <pub-date pub-type="epub" iso-8601-date="2020-11-30">
        <day>30</day>
        <month>11</month>
        <year>2020</year>
      </pub-date>
      <volume>1</volume>
      <issue>1</issue>
      <fpage>23</fpage>
      <lpage>28</lpage>
      <history>
        <date date-type="received">
          <day>26</day>
          <month>03</month>
          <year>2020</year>
        </date>
        <date date-type="accepted">
          <day>10</day>
          <month>11</month>
          <year>2020</year>
        </date>
        <date date-type="online">
          <day>30</day>
          <month>11</month>
          <year>2020</year>
        </date>
      </history>
      <permissions>
        <copyright-statement>© </copyright-statement>
        <copyright-year>2020</copyright-year>
        <copyright-holder>Roya Davoodi, et al.</copyright-holder>
        <license xlink:href="http://creativecommons.org/licenses/by/4.0/" xlink:type="simple">
          <license-p>This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.</license-p>
        </license>
      </permissions>
      <self-uri xlink:href="http://openaccesspub.org/jrnm/article/1503">This article is available from http://openaccesspub.org/jrnm/article/1503</self-uri>
      <abstract>
        <sec id="idm1842264836">
          <title>Introduction</title>
          <p>Given the high radiation tissue sensitivity of pediatric patients, it is necessary to monitor their received dose in order to optimize radiation protection. The first aim of this study was to evaluate of the entrance surface dose (ESD) in pediatric patients undergoing chest x-ray at the main hospital of Dezful, Iran. The second aim was to compare our results with the established dose reference levels (DRL).</p>
        </sec>
        <sec id="idm1842263396">
          <title>Materials and Methods</title>
          <p>The studied population included 204 pediatric patients less than 15 year who were referred to chest x-ray. A calibrated dose area product meter (DAP-meter) with permanent installation on x-ray unit was used to radiation dose measurements. For each patient, the demographic data, exposure parameters and the dose read by the DAP-meter were recorded and ESD was calculated using standard mathematical formula.</p>
        </sec>
        <sec id="idm1842263828">
          <title>Results</title>
          <p>The average value of ESD was 119 μGy in patients less than 15 years. This value was 51.3, 122.3, 131.5 and 171.2 μGy for the age groups less than 1 year, 1 to 5 years, 5 to 10 years and 10 to 15 year, respectively. A statistical significant difference was seen between ESD values ​​in different age groups (P&lt;0.001), whereas no statistical difference was seen between ESD values in ​ girls and boys (P =0.993).</p>
        </sec>
        <sec id="idm1842263684">
          <title>Conclusion</title>
          <p>Pediatric patients in hospital investigated (except age group less than 1 year) are subjected to unnecessary radiation exposure, especially due to use of non-optimized x-ray protocols.</p>
        </sec>
      </abstract>
      <kwd-group>
        <kwd>Dose area product</kwd>
        <kwd>Chest x-ray</kwd>
        <kwd>Pediatric</kwd>
        <kwd>Patient</kwd>
        <kwd>Radiation</kwd>
        <kwd>ESD</kwd>
      </kwd-group>
      <counts>
        <fig-count count="1"/>
        <table-count count="1"/>
        <page-count count="6"/>
      </counts>
    </article-meta>
  </front>
  <body>
    <sec id="idm1842263612" sec-type="intro">
      <title>Introduction</title>
      <p>Although discovery of X-rays by Wilhelm Conrad Rontgen in 1895 has revolutionized medical care, their use involves some potential health risks to individual patients undergoing diagnostic and therapeutic procedures <xref ref-type="bibr" rid="ridm1849453740">1</xref>. This risk has established to be inversely proportion with patients age, suggests high radiation tissue sensitivity of pediatric patients. Several studies have reported that pediatrics to be as much as 10 times more susceptible to radiation-induced carcinogenesis than adult <xref ref-type="bibr" rid="ridm1849523788">2</xref><xref ref-type="bibr" rid="ridm1849533868">3</xref><xref ref-type="bibr" rid="ridm1849318756">4</xref>. Therefore, it is necessary to monitor their received radiation dose, especially for frequent X-ray examinations in order to optimize radiation protection.</p>
      <p>Chest X-ray is one of the frequent X-ray examinations requests by pediatricians for pediatric patients <xref ref-type="bibr" rid="ridm1849318756">4</xref>. Even though the radiation dose associated with a singular chest X-ray is low, but due to wide frequency, radiation dose optimization should be considered <xref ref-type="bibr" rid="ridm1849318756">4</xref>. Evidence showed that there is wide variation in the amount of radiation dose received by pediatric patients for the same type of X-ray                   examinations such as the chest X-rays <xref ref-type="bibr" rid="ridm1849314292">5</xref><xref ref-type="bibr" rid="ridm1849302852">6</xref><xref ref-type="bibr" rid="ridm1849304940">7</xref>. These variations result in some patients receives more radiation dose than needed. Accordingly, the international commission on radiological protection (ICRP) has recommended diagnostic reference levels (DRL) as a guide to protect patients from undue radiation exposure <xref ref-type="bibr" rid="ridm1849288516">8</xref>. DRL are determined through the third quartile of the average entrance surface dose (ESD) distribution <xref ref-type="bibr" rid="ridm1849284988">9</xref>. ESD which is defined as the absorbed dose at the entrance surface of the tissue, has been identified as the best indicator for monitoring patients' dose during X-ray examinations <xref ref-type="bibr" rid="ridm1849278188">10</xref><xref ref-type="bibr" rid="ridm1849274732">11</xref>. It can measure directly using thermoluminescent dosimeters (TLD) or indirectly by a mathematical formula based on tube output at free-air or dose area product meter (DAP-meter) <xref ref-type="bibr" rid="ridm1849278188">10</xref><xref ref-type="bibr" rid="ridm1849269908">12</xref><xref ref-type="bibr" rid="ridm1849281284">13</xref>. There are rarely studies on radiation dose measurement during pediatric chest X-rays in Iran. Bahreyni Toossi et al. <xref ref-type="bibr" rid="ridm1849314292">5</xref> reported an ESD value of 76.3 µGy and DRL value of 88 µGy for neonatal chest X-rays in Mashhad. Similarly, Faghihi et al <xref ref-type="bibr" rid="ridm1849250308">14</xref> reported an ESD value of 56.6 µGy for neonatal chest X-rays in Shiraz.</p>
      <p>The aim of this study was to evaluate the ESD in pediatric patients undergoing chest X-ray using TLD and DAP-meter at large teaching hospital of Dezful-Iran.</p>
    </sec>
    <sec id="idm1842264404" sec-type="materials">
      <title>Materials and Methods</title>
      <p>This study was performed during a period of 6-months in the radiology center of the teaching hospital of Dezful University of Medical Sciences (Dr. Ganjavian). Exposures were performed using a single digital radiography unit (VARIAN X-ray system, UAS) with total filtration of 3-mm aluminum and focal spot of 1-mm<sup>2</sup>. This unit has a fixed                         anti-scatter radiation grid that allows all exposure to be performed using the grid. Prior to the study, approval was provided from the university ethic committee to proceed. Moreover, informed consent was obtained from the parents. The studied population included 204 pediatric patients who were referred for a clinically indicated chest x-ray. Patients were considered eligible for inclusion if their age was less than 15 years, have anteroposterior (AP) or posteroanterior (PA) view of the chest x-ray on their request sheet and their parents have signed informed consent form. The emergency patients and patients with a lateral view of the chest x-ray were excluded from the study. Following literature <xref ref-type="bibr" rid="ridm1849302852">6</xref><xref ref-type="bibr" rid="ridm1849269908">12</xref><xref ref-type="bibr" rid="ridm1849243972">15</xref>, patients were divided into four age groups of less than 1 year, 1 to 5 years, 5 to 10 years and 10 to 15 years. For each patient, the demographic data and exposure parameters was measured and recorded. A calibrated dose area product meter               (DAP-meter) with permanent installation on an x-ray unit was used for radiation dose measurements. DAP is defined as the absorbed dose multiplied by the area of tissue irradiated which reflects dose in the radiation field together with area of tissue irradiated. ESD was calculated using the follow mathematical formula.</p>
      <fig id="idm1841378956">
        <graphic xlink:href="images/image1.png" mime-subtype="png"/>
      </fig>
      <p>Where, A is the area of radiation field on the patient skin (cm<sup>2</sup>), DAP: dose measured by DAP-meter (mGy×cm<sup>2</sup>), FSD: x-ray focus to skin distance (m), FFD: x-ray focus to film distance (m) and BSF: back scatter factor.</p>
      <sec id="idm1842261020">
        <title>Statistic</title>
        <p>Data were entered into Microsoft Excel (Microsoft Inc., Redmond, WA) and statistical analysis was performed using SPSS software (IBM, Armonk, New York). The one-way analysis of variance (ANOVA) was used to measure and compare ESD values in different age groups. Moreover, independent paired t-test was used to compare ESD values in the boy and girl subjects.</p>
      </sec>
    </sec>
    <sec id="idm1842263108" sec-type="results">
      <title>Results</title>
      <p>Of 204 pediatric patients enrolled in the study, 81 (39.7%) were girl and 123 (60.3%) were boy. The characteristic of patients and exposure parameters are presented in <xref ref-type="table" rid="idm1841376436">Table 1</xref>. The average value of ESD was 119 μGy in patients less than 15 years. This value was 51.3, 122.3, 131.5 and 171.2 μGy for the age groups less than 1 year, 1 to 5 years, 5 to 10 years and 10 to 15 years, respectively (<xref ref-type="fig" rid="idm1841323284">Figure 1</xref>). There was a statistically significant difference between ESD value in different age groups (P&lt;0.001). Increasing patients' age resulted in increasing the ESD value. There was significant correlation between applied current-time-product (mAs) and tube potential (kVp) with ESD values, whereas no meaningful correlation was found for patients' sex (P=0.993).</p>
      <table-wrap id="idm1841376436">
        <label>Table 1.</label>
        <caption>
          <title> Characteristic of patients and exposure parameters during pediatric chest x-rays.</title>
        </caption>
        <table rules="all" frame="box">
          <tbody>
            <tr>
              <td>
                <bold>Variable</bold>
              </td>
              <td>
                <bold>Average</bold>
                <bold>
(range)</bold>
              </td>
              <td>
                <bold>Standard deviation</bold>
              </td>
            </tr>
            <tr>
              <td>Weight (kg)</td>
              <td>17.87 (2.50-50)</td>
              <td>11.8</td>
            </tr>
            <tr>
              <td>Height (cm)</td>
              <td>83.25(12-140)</td>
              <td>20.51</td>
            </tr>
            <tr>
              <td>A (cm2)</td>
              <td>24.71(18-30)</td>
              <td>4.73</td>
            </tr>
            <tr>
              <td>FFD (cm)</td>
              <td>118.87(35-150)</td>
              <td>24.29</td>
            </tr>
            <tr>
              <td>FSD (cm)</td>
              <td>104.2(18-123)</td>
              <td>18.4</td>
            </tr>
            <tr>
              <td>kVp</td>
              <td>67.59  (50-90)</td>
              <td>9.08</td>
            </tr>
            <tr>
              <td>mAs</td>
              <td>8.75(4-20)</td>
              <td>3.55</td>
            </tr>
            <tr>
              <td>DAP (mGy.cm2)</td>
              <td>33.94(4.8-87)</td>
              <td>19.86</td>
            </tr>
          </tbody>
        </table>
        <table-wrap-foot>
          <fn id="idm1842232468">
            <label/>
            <p>Abbreviations: A. area of radiation field on patients' skin, FFD. Focus to film distance, FSD. Focus to skin distance, DAP. Dose area product</p>
          </fn>
        </table-wrap-foot>
      </table-wrap>
      <fig id="idm1841323284">
        <label>Figure 1.</label>
        <caption>
          <title> Average ESD in pediatric patients undergoing chest x-ray as a function of patient age</title>
        </caption>
        <graphic xlink:href="images/image2.jpg" mime-subtype="jpg"><alt-text>Figure 1. Average ESD in pediatric patients undergoing chest x-ray as a function of patient age</alt-text></graphic>
      </fig>
    </sec>
    <sec id="idm1842232684" sec-type="discussion">
      <title>Discussion</title>
      <p>Patient radiation dose measurement is crucial in order to optimize radiological protection in x-ray centers. This study provides useful information about the radiation dose received by pediatric patients undergoing chest x-ray at our hospital. It can be used for comparing patients' dose with the established DRL values so that patients do not receive unnecessary radiation exposure. According to our results, the average ESD values for patients less than 1 year, 1 to 5 years, 5 to 10 years and 10 to 15 years were 51.3, 122.3, 131.5 and 171.2 μGy which are consistent with 66.14, 104.58, 135.77 and 139.03 μGy reported by Atalabi et al. for pediatric chest x-rays, respectively <xref ref-type="bibr" rid="ridm1849302852">6</xref>. The ESD value of 51.3 μGy measured in this study for the age group less than 1 year is consistent with 56.6 and 52 μGy reported by Faghihi et al <xref ref-type="bibr" rid="ridm1849250308">14</xref> and Smans et al <xref ref-type="bibr" rid="ridm1849240372">16</xref> for neonatal chest x-rays, whereas, it was lower than 76.3 μGy reported by Bahreyni Toossi et al <xref ref-type="bibr" rid="ridm1849314292">5</xref>. Both agreement and discordance were present between our study and the study performed by Ademola et al. <xref ref-type="bibr" rid="ridm1849243972">15</xref> on pediatric chest x-rays. They reported ESD values of 111 and 159 μGy for the age group of 1 to 5 years and 5 to 10 years which are similar to 122.3 and 131.5 μGy obtained in our study. However, they reported an ESD value of 620 μGy for 10 to 15 year patients which are substantially higher than 171.2 μGy obtained in our study. Similarly, our results are inconsistent with ESD values of 182, 172, 340 and 587 μGy reported by Zewdu et al for patients less than 1 year, 1 to 5 years, 5 to 10 years and 10 to 15 years during chest x-rays <xref ref-type="bibr" rid="ridm1849269908">12</xref>. These variations could be explained by variation in the applied FSD and exposure parameters (kVp and mAs), patient habitus, use or not use of an anti-scatter grid and x-ray units used in these studies. We found no significant correlation of patients' sex and weight with ESD values, whereas significant correlation was seen for the applied kVp and mAs. These results are consistent with the literature <xref ref-type="bibr" rid="ridm1849302852">6</xref>.</p>
      <p>The DRL values of 50, 70 and 120 μGy have been recommended for a 1 year, 5 year and 10 year pediatric patient undergoing chest x-ray, respectively <xref ref-type="bibr" rid="ridm1849304940">7</xref>. Our results are consistent with the recommended DRL value of 50 μGy for age group less than 1 year. However, for age groups 1 to 5 years and 5 to 10 years, the ESD values of 122.3 and 131.5 μGy measured in this study are higher than recommended DRL values of 70 and 120 μGy which refers to non-optimization of radiological protection for these age groups. Patient dose is particularly influenced by variation in the applied exposure parameters <xref ref-type="bibr" rid="ridm1849269908">12</xref>. The European Commission (EC) has recommended tube potential (kVp) of 60 to 80 for pediatric patients less than 1 year and 100 to 120 for 5 years and higher <xref ref-type="bibr" rid="ridm1849236196">17</xref>. The use of tube potential less than 60 kVp has also been discouraged. This advice comes from this fact that appropriate combined use of high kVp and low mAs would result in reducing patient dose <xref ref-type="bibr" rid="ridm1849314292">5</xref>. In this study, the radiographers used 60 to 65 kVp for patients less than 1 year, 63 to 70 for 1 to 5 years, 65 to 70 for 5 to 10 years and 65 to 75 kVp for 10 to 15 year patients. These inappropriate exposure parameters clearly indicate that the protocols used for pediatric chest x-rays (except for the age group less than 1 year) are not optimized. Such concern has been reported in the literature <xref ref-type="bibr" rid="ridm1849269908">12</xref><xref ref-type="bibr" rid="ridm1849243972">15</xref>.</p>
    </sec>
    <sec id="idm1842231820" sec-type="conclusions">
      <title>Conclusion</title>
      <p>This study indicated that 1 to 15 year pediatric patients in the hospital investigated are subjected to unnecessary radiation exposure, especially due to use of non-optimized x-ray protocols. We recommend provision of and adherence to a written departmental radiation safety protocol in order to protect pediatric patients from undue exposure to radiation.</p>
    </sec>
  </body>
  <back>
    <ack>
      <p>This study was extracted from the MSc thesis of the first author and a research project approved by Payam-Noor University of Mashhad.</p>
    </ack>
    <ref-list>
      <ref id="ridm1849453740">
        <label>1.</label>
        <mixed-citation xlink:type="simple" publication-type="journal">
          <name>
            <surname>Ward</surname>
            <given-names>R</given-names>
          </name>
          <name>
            <surname>Carroll</surname>
            <given-names>W D</given-names>
          </name>
          <name>
            <surname>Cunningham</surname>
            <given-names>P</given-names>
          </name>
          <name>
            <surname>Ho</surname>
            <given-names>S-A</given-names>
          </name>
          <name>
            <surname>Jones</surname>
            <given-names>M</given-names>
          </name>
          <name>
            <surname>Lenney</surname>
            <given-names>W</given-names>
          </name>
          <article-title>Radiation dose from common radiological investigations and cumulative exposure in children with cystic fibrosis: an observational study from a single UK centre</article-title>
          <date>
            <year>2017</year>
          </date>
          <source>BMJ open</source>
          <volume>7</volume>
          <issue>8</issue>
          <fpage>17548</fpage>
        <pub-id pub-id-type="doi">10.1136/bmjopen-2017-017548</pub-id></mixed-citation>
      </ref>
      <ref id="ridm1849523788">
        <label>2.</label>
        <mixed-citation xlink:type="simple" publication-type="journal">
          <name>
            <surname>Curtis</surname>
            <given-names>J R</given-names>
          </name>
          <article-title>Computed tomography shielding methods: a literature review. Radiologic technology</article-title>
          <date>
            <year>2010</year>
          </date>
          <volume>81</volume>
          <issue>5</issue>
          <fpage>428</fpage>
          <lpage>36</lpage>
        </mixed-citation>
      </ref>
      <ref id="ridm1849533868">
        <label>3.</label>
        <mixed-citation xlink:type="simple" publication-type="journal">
          <name>
            <surname>Hohl</surname>
            <given-names>C</given-names>
          </name>
          <name>
            <surname>Wildberger</surname>
            <given-names>J</given-names>
          </name>
          <name>
            <surname>Süß</surname>
            <given-names>C</given-names>
          </name>
          <name>
            <surname>Thomas</surname>
            <given-names>C</given-names>
          </name>
          <name>
            <surname>Mühlenbruch</surname>
            <given-names>G</given-names>
          </name>
          <name>
            <surname>Schmidt</surname>
            <given-names>T</given-names>
          </name>
          <article-title>Radiation dose reduction to breast and thyroid during MDCT: effectiveness of an in-plane bismuth shield</article-title>
          <date>
            <year>2006</year>
          </date>
          <source>Acta Radiologica</source>
          <volume>47</volume>
          <issue>6</issue>
          <fpage>562</fpage>
          <lpage>567</lpage>
        <pub-id pub-id-type="doi">10.1080/02841850600702150</pub-id></mixed-citation>
      </ref>
      <ref id="ridm1849318756">
        <label>4.</label>
        <mixed-citation xlink:type="simple" publication-type="journal">
          <name>
            <surname>Kostova-Lefterova</surname>
            <given-names>D</given-names>
          </name>
          <name>
            <surname>Taseva</surname>
            <given-names>D</given-names>
          </name>
          <name>
            <surname>Hristova-Popova</surname>
            <given-names>J</given-names>
          </name>
          <name>
            <surname>Vassileva</surname>
            <given-names>J</given-names>
          </name>
          <article-title>Optimisation of paediatric chest radiography. Radiation protection dosimetry.165(1-4):</article-title>
          <date>
            <year>2015</year>
          </date>
          <fpage>231</fpage>
          <lpage>4</lpage>
        <pub-id pub-id-type="doi">10.1093/rpd/ncv119</pub-id></mixed-citation>
      </ref>
      <ref id="ridm1849314292">
        <label>5.</label>
        <mixed-citation xlink:type="simple" publication-type="journal">
          <name>
            <surname>MTB</surname>
            <given-names>Toossi</given-names>
          </name>
          <name>
            <surname>Malekzadeh</surname>
            <given-names>M</given-names>
          </name>
          <article-title>Radiation dose to newborns in neonatal intensive care units</article-title>
          <date>
            <year>2012</year>
          </date>
          <source>Iranian Journal of</source>
          <volume>9</volume>
          <issue>3</issue>
          <fpage>145</fpage>
        </mixed-citation>
      </ref>
      <ref id="ridm1849302852">
        <label>6.</label>
        <mixed-citation xlink:type="simple" publication-type="journal">
          <name>
            <surname>Atalabi</surname>
            <given-names>O M</given-names>
          </name>
          <name>
            <surname>BidemiI</surname>
            <given-names>A</given-names>
          </name>
          <name>
            <surname>Adekanmi</surname>
            <given-names>A J</given-names>
          </name>
          <name>
            <surname>Samuel</surname>
            <given-names>O A</given-names>
          </name>
          <article-title>Entrance surface dose from pediatric diagnostic x-ray examinations in a developing world setting: are we'ALARA principle'compliant?</article-title>
          <date>
            <year>2013</year>
          </date>
          <source>British Journal of Medicine and Medical</source>
          <volume>3</volume>
          <issue>4</issue>
          <fpage>2288</fpage>
        </mixed-citation>
      </ref>
      <ref id="ridm1849304940">
        <label>7.</label>
        <mixed-citation xlink:type="simple" publication-type="journal">
          <name>
            <surname>Kim</surname>
            <given-names>B H</given-names>
          </name>
          <name>
            <surname>Do</surname>
            <given-names>K-H</given-names>
          </name>
          <name>
            <surname>Goo</surname>
            <given-names>H W</given-names>
          </name>
          <name>
            <surname>Yang</surname>
            <given-names>D H</given-names>
          </name>
          <name>
            <surname>Oh</surname>
            <given-names>S Y</given-names>
          </name>
          <name>
            <surname>Kim</surname>
            <given-names>H J</given-names>
          </name>
          <article-title>National survey of radiation doses of pediatric chest radiography in Korea: analysis of the factors affecting radiation doses. Korean journal of radiology</article-title>
          <date>
            <year>2012</year>
          </date>
          <volume>13</volume>
          <issue>5</issue>
          <fpage>610</fpage>
          <lpage>7</lpage>
        <pub-id pub-id-type="doi">10.3348/kjr.2012.13.5.610</pub-id></mixed-citation>
      </ref>
      <ref id="ridm1849288516">
        <label>8.</label>
        <mixed-citation xlink:type="simple" publication-type="journal">
          <name>
            <surname>Nikupaavo</surname>
            <given-names>U</given-names>
          </name>
          <name>
            <surname>Kaasalainen</surname>
            <given-names>T</given-names>
          </name>
          <name>
            <surname>Reijonen</surname>
            <given-names>V</given-names>
          </name>
          <name>
            <surname>Ahonen</surname>
            <given-names>S-M</given-names>
          </name>
          <name>
            <surname>Kortesniemi</surname>
            <given-names>M</given-names>
          </name>
          <article-title>Lens dose in routine head CT: comparison of different optimization methods with anthropomorphic phantoms</article-title>
          <date>
            <year>2015</year>
          </date>
          <source>American Journal of Roentgenology</source>
          <volume>204</volume>
          <issue>1</issue>
          <fpage>117</fpage>
          <lpage>23</lpage>
        <pub-id pub-id-type="doi">10.2214/ajr.14.12763</pub-id></mixed-citation>
      </ref>
      <ref id="ridm1849284988">
        <label>9.</label>
        <mixed-citation xlink:type="simple" publication-type="journal">
          <name>
            <surname>Freitas</surname>
            <given-names>M B</given-names>
          </name>
          <name>
            <surname>Yoshimura</surname>
            <given-names>E M</given-names>
          </name>
          <article-title>Diagnostic reference levels for the most frequent radiological examinations carried out in Brazil. Revista Panamericana de Salud Pública</article-title>
          <date>
            <year>2009</year>
          </date>
          <volume>25</volume>
          <fpage>95</fpage>
          <lpage>104</lpage>
        <pub-id pub-id-type="doi">10.1590/s1020-49892009000200001</pub-id></mixed-citation>
      </ref>
      <ref id="ridm1849278188">
        <label>10.</label>
        <mixed-citation xlink:type="simple" publication-type="journal">
          <name>
            <surname>Jornet</surname>
            <given-names>N</given-names>
          </name>
          <name>
            <surname>Muñoz</surname>
            <given-names>J</given-names>
          </name>
          <name>
            <surname>Martin-Viera</surname>
            <given-names>J</given-names>
          </name>
          <name>
            <surname>Jurado</surname>
            <given-names>D</given-names>
          </name>
          <name>
            <surname>Pallerol</surname>
            <given-names>R</given-names>
          </name>
          <name>
            <surname>Gultresa</surname>
            <given-names>J</given-names>
          </name>
          <source>DETERMINATION OF ENTRANCE SURFACE DOSE IN STANDARD EXPLORATIONS IN RADIODIAGNOSTIC</source>
        </mixed-citation>
      </ref>
      <ref id="ridm1849274732">
        <label>11.</label>
        <mixed-citation xlink:type="simple" publication-type="journal">
          <name>
            <surname>Ofori</surname>
            <given-names>K</given-names>
          </name>
          <name>
            <surname>Gordon</surname>
            <given-names>S W</given-names>
          </name>
          <name>
            <surname>Akrobortu</surname>
            <given-names>E</given-names>
          </name>
          <name>
            <surname>Ampene</surname>
            <given-names>A A</given-names>
          </name>
          <name>
            <surname>Darko</surname>
            <given-names>E O</given-names>
          </name>
          <article-title>Estimation of adult patient doses for selected X-ray diagnostic examinations</article-title>
          <date>
            <year>2014</year>
          </date>
          <source>Journal of Radiation Research and Applied Sciences</source>
          <volume>7</volume>
          <issue>4</issue>
          <fpage>459</fpage>
          <lpage>62</lpage>
        <pub-id pub-id-type="doi">10.1016/j.jrras.2014.08.003</pub-id></mixed-citation>
      </ref>
      <ref id="ridm1849269908">
        <label>12.</label>
        <mixed-citation xlink:type="simple" publication-type="journal">
          <name>
            <surname>Zewdu</surname>
            <given-names>M</given-names>
          </name>
          <name>
            <surname>Kadir</surname>
            <given-names>E</given-names>
          </name>
          <name>
            <surname>Berhane</surname>
            <given-names>M</given-names>
          </name>
          <article-title>Assessment of pediatrics radiation dose from routine x-ray examination at Jimma University Hospital, Southwest Ethiopia. Ethiopian journal of health sciences</article-title>
          <date>
            <year>2017</year>
          </date>
          <volume>27</volume>
          <issue>5</issue>
          <fpage>481</fpage>
          <lpage>90</lpage>
        <pub-id pub-id-type="doi">10.4314/ejhs.v27i5.6</pub-id></mixed-citation>
      </ref>
      <ref id="ridm1849281284">
        <label>13.</label>
        <mixed-citation xlink:type="simple" publication-type="journal">
          <name>
            <surname>Gholami</surname>
            <given-names>M</given-names>
          </name>
          <name>
            <surname>Maziar</surname>
            <given-names>A</given-names>
          </name>
          <name>
            <surname>Khosravi</surname>
            <given-names>H</given-names>
          </name>
          <name>
            <surname>Ebrahimzadeh</surname>
            <given-names>F</given-names>
          </name>
          <name>
            <surname>Mayahi</surname>
            <given-names>S</given-names>
          </name>
          <article-title>Diagnostic reference levels (DRLs) for routine X-ray examinations in Lorestan province</article-title>
          <date>
            <year>2015</year>
          </date>
          <source>Iran. International Journal Of Radiation Research</source>
          <volume>13</volume>
          <issue>1</issue>
          <fpage>85</fpage>
        </mixed-citation>
      </ref>
      <ref id="ridm1849250308">
        <label>14.</label>
        <mixed-citation xlink:type="simple" publication-type="journal">
          <name>
            <surname>Faghihi</surname>
            <given-names>R</given-names>
          </name>
          <name>
            <surname>Mehdizadeh</surname>
            <given-names>S</given-names>
          </name>
          <name>
            <surname>Sina</surname>
            <given-names>S</given-names>
          </name>
          <name>
            <surname>Alizadeh</surname>
            <given-names>F N</given-names>
          </name>
          <name>
            <surname>Zeinali</surname>
            <given-names>B</given-names>
          </name>
          <name>
            <surname>Kamyab</surname>
            <given-names>G R</given-names>
          </name>
          <article-title>Radiation dose to neonates undergoing X-ray imaging in special care baby units in Iran. Radiation protection dosimetry</article-title>
          <date>
            <year>2011</year>
          </date>
          <volume>150</volume>
          <issue>1</issue>
          <fpage>55</fpage>
          <lpage>9</lpage>
        <pub-id pub-id-type="doi">10.1093/rpd/ncr373</pub-id></mixed-citation>
      </ref>
      <ref id="ridm1849243972">
        <label>15.</label>
        <mixed-citation xlink:type="simple" publication-type="journal">
          <name>
            <surname>Ademola</surname>
            <given-names>A</given-names>
          </name>
          <name>
            <surname>Obed</surname>
            <given-names>R</given-names>
          </name>
          <name>
            <surname>Adejumobi</surname>
            <given-names>C</given-names>
          </name>
          <name>
            <surname>Abodunrin</surname>
            <given-names>O</given-names>
          </name>
          <name>
            <surname>Alabi</surname>
            <given-names>O</given-names>
          </name>
          <name>
            <surname>Oladapo</surname>
            <given-names>M</given-names>
          </name>
          <article-title>Assessment of Entrance Skin Dose in routine x-ray examinations of chest, skull, abdomen and pelvis of children in five selected hospitals in Nigeria</article-title>
          <date>
            <year>2013</year>
          </date>
          <source>IOSR Journal of Applied Physics</source>
          <volume>5</volume>
          <issue>2</issue>
          <fpage>47</fpage>
          <lpage>50</lpage>
        </mixed-citation>
      </ref>
      <ref id="ridm1849240372">
        <label>16.</label>
        <mixed-citation xlink:type="simple" publication-type="journal">
          <name>
            <surname>Smans</surname>
            <given-names>K</given-names>
          </name>
          <name>
            <surname>Struelens</surname>
            <given-names>L</given-names>
          </name>
          <name>
            <surname>Smet</surname>
            <given-names>M</given-names>
          </name>
          <name>
            <surname>Bosmans</surname>
            <given-names>H</given-names>
          </name>
          <name>
            <surname>Vanhavere</surname>
            <given-names>F</given-names>
          </name>
          <article-title>Patient dose in neonatal units. Radiation protection dosimetry</article-title>
          <date>
            <year>2008</year>
          </date>
          <volume>131</volume>
          <issue>1</issue>
          <fpage>143</fpage>
          <lpage>7</lpage>
        <pub-id pub-id-type="doi">10.1093/rpd/ncn237</pub-id></mixed-citation>
      </ref>
      <ref id="ridm1849236196">
        <label>17.</label>
        <mixed-citation xlink:type="simple" publication-type="journal">
          <name>
            <surname>European</surname>
            <given-names>Union</given-names>
          </name>
          <article-title>European Commission. Directorate-General XII-Science R, Development. European guidelines on quality criteria for diagnostic radiographic images in paediatrics: Office for Official Publications of the European Communities;</article-title>
          <date>
            <year>1996</year>
          </date>
        </mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>